Mityvac MV5545 Manual de usuario

Busca en linea o descarga Manual de usuario para Motor Mityvac MV5545. Mityvac MV5545 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 42
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
USERS MANUAL
Have a technical question?
If you have questions, or require technical
service, please contact our trained service
technicians at:
1-314-679-4200 ext. 4782
Monday Friday 7:30 am to 4:15 pm CST
Visit our website at www.mityvac.com for
new products, catalogs, and instructions
for product use.
Need service parts?
To order replacement or service parts, visit us
online at www.mityvacparts.com or call toll free
1-800-992-9898.
FST PRO FUEL SYSTEM TESTER
MODEL MV5545
SEPTEMBER - 2007 Form 824127 Section - MV59-1
Vista de pagina 0
1 2 3 4 5 6 ... 41 42

Indice de contenidos

Pagina 1 - MODEL MV5545

USER’S MANUALHave a technical question?If you have questions, or require technicalservice, please contact our trained servicetechnicians at:1-314-679-

Pagina 2 - Contents

Flex Hose ConnectionsIn many cases it is convenient to connect the FST Pro into the fueldelivery system at a location where a flexible rubber hose is

Pagina 3 - Components, Service Parts

Form 824127 Page Number - 11Principle of OperationFuel Delivery BasicsModern fuel injected engines rely on precision fuel delivery toperform at peak o

Pagina 4 - Accessories

In regards to return fuel systems, knowing the pressure and flow atidle is a very good indication as to whether the fuel system isfunctioning properly

Pagina 5 - Service Parts

Fig. 20Form 824127 Page Number - 13When the valve is rotated to the BYPASS position pointing up, fuel isrouted through the bypass port located on the

Pagina 6 - Fuel System Test Adapters

Fig. 21Fig. 22Page Number - 14 Form 824127Types of Fuel Delivery SystemsFor the purpose of accurately applying and testing with the FST Pro,today’s fu

Pagina 7

Fig. 25Fig. 24Fig. 23Form 824127 Page Number - 15Returnless fuel systems (mechanically regulated) were pioneered byChrysler in the mid-90s. Since that

Pagina 8 - Connections

Fig. 27Fig. 26Page Number - 16 Form 824127Electronically RegulatedFord began developing an electronically regulated returnless fueldelivery system in

Pagina 9 - Banjo Connections

Form 824127 Page Number - 17Fuel System ComponentsThe modern fuel delivery system is comprised of several criticalcomponents. A malfunction of one or

Pagina 10 - Flex Hose Connections

Page Number - 18 Form 824127A clogged inlet strainer can starve the fuel pump of fuel, causingit to cavitate. Cavitation will create rapid changes in

Pagina 11 - Principle of Operation

Fig. 28Fig. 29Fig. 30Form 824127 Page Number - 19Setup and InstallationDetermining Where to Install the FSTInline ConnectionRegardless of the type of

Pagina 12 - Simulating Engine Demand

ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Safety Precautions . . . . . . . .

Pagina 13

Fig. 35reduce fuel spillage, whenever possible, try to select the requiredadapters before disconnecting the fuel line, and have them ready toinstall.S

Pagina 14 - Returnless Fuel Systems

7. Connect the hose extending from the flowmeter connectionlabeled “IN”, to the other end of the adapter (Fig. 36).8. Install the second FST connectio

Pagina 15 - Mechanically Regulated

Fig. 40Fig. 39Fig. 41Read topof floatPage Number - 22 Form 824127Testing and DiagnosticsTesting and diagnostic procedures vary depending on the type o

Pagina 16 - Electronically Regulated

Fig. 42Fig. 43Form 824127 Page Number - 23At idle, the volume of fuel flowing through the tester should remainsteady between 0.3 and 0.6 gallons per m

Pagina 17 - Fuel System Components

Fig. 44Page Number - 24 Form 824127continues to experience symptoms of a fuel delivery malfunction, itcould be caused by contaminated fuel, faulty fue

Pagina 18 - Fuel Lines

Form 824127 Page Number - 25Under-restricting Fuel Pressure RegulatorAn under-restricting pressure regulator will cause the idle pressure inZones 1 an

Pagina 19 - Setup and Installation

Fig. 46Fig. 45Fig. 47Page Number - 26 Form 824127Returnless Fuel Delivery Systems(Mechanically Regulated)At this point, it is assumed that the FST has

Pagina 20 - Installing the FST Pro

Fig. 49Fig. 48Form 824127 Page Number - 27OPEN position.Peak Demand Test7. Note the vehicle’s engine size and maximum engine speed (RPM).Refer to the

Pagina 21

Fig. 50A clogged inlet strainer can cause the fuel pump to cavitate becauseit is starved for fuel. Cavitation will create rapid changes in fuel densi-

Pagina 22 - Testing and Diagnostics

Fig. 51Fig. 52Fig. 53After connecting the FST, it is normal to have air trapped in thefuel lines and flowmeter. Cycling the ignition switch (or cranki

Pagina 23 - Diagnosing the Results

IntroductionThe Mityvac FST Pro Fuel System Tester is an advanceddiagnostic tool designed for troubleshooting and pinpointingcommon automotive fuel de

Pagina 24 - Zone 3 - Yellow

Fig. 55Fig. 549. With the car idling, rotate the flow control valve past the 90°CLOSED position towards BYPASS (Fig. 54). Adjust the valve untilthe fl

Pagina 25

ty, causing the float in the FST flowmeter to bounce up and downduring the peak flow and/or capability test. It can also cause the nee-dle on the pres

Pagina 26 - (Mechanically Regulated)

Fig. 56Fig. 57Page Number - 32 Form 8241275. Turn off the engine and immediately clamp off the FST inlet hoserunning to the tester from the fuel suppl

Pagina 27

the hose is clamped, quickly disconnect the hose from the fuelsystem before the pressure has time to build. Try to keep a shoptowel wrapped around the

Pagina 28 - (Electronically Regulated)

Page Number - 34 Form 824127Engine Size Engine Speed (RPM)liters CID 3000 4000 5000 6000 7000 80001.0 61 0.05 0.06 0.07 0.09 0.10 0.121.2 73 0.06 0.07

Pagina 29

Form 824127 Page Number - 35Engine Size Engine Speed (RPM)liters CID 3000 4000 5000 6000 7000 80001.0 61 0.19 0.23 0.26 0.34 0.38 0.451.2 73 0.23 0.26

Pagina 30

Page Number - 36 Form 824127ResultsScenarioIdlePressureIdle FlowPeak PressurePeak FlowPotential Causes1 Normal NormalGreater thanmaximum fuelvolume re

Pagina 31 - Pressure Leakdown Test

Appendix BReturn Fuel System Diagnostic GuideScenario 2Diagnosis:A restriction to the supply of fuel to the engine such as aclogged inlet strainer, in

Pagina 32 - Disconnecting the FST

Page Number - 38 Form 824127ResultsScenarioIdlePressurePeak FlowPeak Demand PressurePotential Causes1 NormalNormal.7 to 1.0 GPM(2.5 to 4.0 LPM)NormalL

Pagina 33

Form 824127 Page Number - 39Appendix CReturnless (Mechanically Regulated)Fuel System Diagnostic GuideScenario 2Diagnosis:A restriction to the supply o

Pagina 34 - Appendix A

MVA5552MVA5549MVA509Standard Kit ComponentsPart Number Description824141 High Pressure Gauge824149 Pressure Relief Hose (1/8"/3mm ID x 6'/1.

Pagina 35

Page Number - 40 Form 824127*See Appendix A for maximum engine fuel volume requirementInlet strainer/sockECM/PCMPressure Transducer/SensorFuel FilterF

Pagina 36

Form 824127 Page Number - 41Appendix DReturnless (Electronically Regulated)Fuel System Diagnostic GuideScenario 2Diagnosis:A restriction to the supply

Pagina 37 - Appendix B

Page Number - 42 Form 824127Lincoln Industrial Standard WarrantyLIMITED WARRANTYLincoln warrants the equipment manufactured and supplied by Lincoln to

Pagina 38

Form 824127 Page Number - 5Service PartsPart Number Description1 824182 Flow Tube Shield2 824177 Male Quick-Connect Fitting3 824176 Bypass Port4 82417

Pagina 39 - Fuel System Diagnostic Guide

Description Applications Order No.ReferenceNo.GM/Chrysler Right AngleTest Port AdapterGM & some Chryslervehicles with7⁄16" x 20thread test po

Pagina 40

Description Applications Order No.ReferenceNo.M16 x 1.5Ball Nose AdapterEuropean vehicleswith CIS fuel systemMVA51911A11BM16 x 1.5 Adapter GM Vortec M

Pagina 41 - Appendix D

AssemblyFor flexibility and ease of storage, the FST Pro features a modulardesign that is quick to assemble and breakdown. Proper assemblyfor testing

Pagina 42

Fig. 9Fig. 11Fig. 10Fuel RailBanjoFittingBanjo BoltBanjo AdapterFuel FilterForm 824127 Page Number - 9To release the connection, press and hold the re

Comentarios a estos manuales